What clients send us. What we deliver back.
Anonymized project records and representative technical examples across all four disciplines. Composite examples are labelled clearly so the basis of each claim is visible.

Utility-scale solar PV design and construction engineering support
One ID-controlled site and electrical model carries a route change through voltage drop, cable length, trench quantities, crossing schedules and drawing references together. The representative design delivers 194.8 MWdc / 150 MWac across 1,120 acres with a 1.299 DC/AC ratio, reduces modeled cable from 550 km to 504 km, and closes 77 of 91 conflicts in the Pathworks coordination register before issue.

Commercial and industrial rooftop solar permit plan sets
A program template with site-specific rule packs standardizes sheet structure, calculations, labels and QA while preserving site-specific roof geometry and AHJ requirements. The representative program delivers 11.597 MWdc / 9.0 MWac across 36 sites and fourteen AHJs, controlled to a program acceptance target of at least 90% of sites issued without major design correction and no more than 0.5 design revisions per site against a 1.6 unmanaged baseline.

Solar-plus-battery energy storage system design
Dispatch assumptions are carried into an equipment-level model so a financial dispatch curve is never issued as an electrical design without a safe, traceable equipment path. The representative design combines 24.001 MWdc of single-axis tracker PV with a 10 MW BESS carrying 44 MWh usable at beginning of life against a 40 MWh guaranteed usable commitment: campus peak falls from 22.4 MW to 14.3 MW, curtailed PV drops from 7.8 GWh to 1.6 GWh, and PV capture rises from 81.8% to 96.3% (approximately 94.4% delivered after 87% round-trip efficiency).

Renewable-energy grid interconnection and power-system studies
An interconnection evidence chain runs from application data through equipment models, study cases, contingencies, violations, mitigation, revised models and utility response, with a model register recording source, version, checksum and owner for every submitted file. The representative package supports a controlled 120 MW export basis, mitigates five project-caused violations, and logs 41 utility comments responded through three controlled cycles.

Wind-farm repowering and electrical balance-of-plant design
A retained/modify/replace disposition is built for every existing asset, using the same asset IDs across the turbine plan, access design, collection circuits, substation interface and demolition package. The representative full repower replaces 68 × 1.5 MW turbines with 40 × 4.2 MW units, raising capacity from 102 MW to 168 MW and net annual energy from 290 GWh to 654 GWh while retaining 65% of access alignment and 36% of trench/duct corridors.